M75 Multifunction installation tester with TRMS DMM, Safety test on electrical plants and Wire mapping Test on LAN cables
M75 is an innovative multifunction installation tester which joins together DMM, Safety Tester and LAN checker features inside a compact and ergonomic user-friendly structure and with a extremely reduced weight (800g only!). The DMM is a professional instrument with TRMS measurement of AC/DC voltage, AC Current (through external clamp), Resistance and Frequency. Additional features are MAX/MIN/AVG function, HOLD function and PEAK detection with Response Time of 1ms, useful for surge currents detection.
Function
GENERAL SPECIFICATIONS
DISPLAY:
Features: Dual numeric, 9999 points
Display update: 2 times/sec
Visible area: 73x73 mm
POWER SUPPLY:
Batteries: 4 batteries 1.5V type LR6-AA-AM3-MN 1500
ELECTRICAL FEATURES:
Conversion: AC 16 Bit, TRMS
Sample frequency: 64 sample/period
MECHANICAL FEATURES:
Dimensions (L x W x H): 240 x 100 x 45mm
Weight (included batteries): approx 630 g
ENVIRONMENTAL CONDITIONS:
Reference temperature: 23°C 5°C
Working temperature: 0° 40°C
Allowed relative humidity: <70%HR
Storage temperature: -10 60°C
Storage humidity: < 70%HR
TEST VERIFIES REFERENCE STANDARDS:
Continuity test with 200mA: IEC/EN61557-4
Insulation resistance: IEC/EN61557-2
Global earth resistance: IEC/EN61557-3
RCDs test: IEC/EN61557-6
Phase sequence indication: IEC/EN61557-7
REFERENCE STANDARDS:
Safety of measuring instruments: IEC/EN61010-1 + A2(1997)
Product type standard: IEC/EN61557-1, 2, 3, 4, 6,7
Insulation: double insulation
Pollution degree: 2
Overvoltage category: CAT III 550V AC Phase - Ground
CAT III 550V AC Phase - Phase
Max height of use: 2000m